{"title":"JA-81M","description":"\u003ch2 style=\"text-align: justify;\"\u003eService explanation for JA-81M\u003c\/h2\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e1 Installation\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2028.jpg\" width=\"480\" height=\"360\"\u003e\u003cbr\u003e\u003cbr\u003eInstallation may only be performed by a certified technician approved by an authorized distributor.\u003cbr\u003eThis detector responds when its magnet is removed. The detector should be placed on the non-moving part of a door or window, and the magnet on the movable part. The detector must be placed vertically. Avoid placing on metal parts that could disturb the magnetic properties and\/or the radio signal. If the door or window is made of metal, we recommend hanging the detector somewhere else and connecting a wired magnetic contact to the detector. \u003cbr\u003e\u003cbr\u003eSee the following instructions:\u003cbr\u003e1. \u003cstrong\u003eOpen the housing\u003c\/strong\u003e by pressing the tab at the bottom.\u003cbr\u003e2. \u003cstrong\u003eScrew the back onto a non-movable part\u003c\/strong\u003e from the door or window.\u003cbr\u003e3. Attach the magnet to the movable part of the door or window. The distance to the detector should not exceed 5mm when the door or window is closed. The bottom of the detector should be flush with the bottom of the magnet. Only one magnet can be placed, this can be on the left or right of the detector.\u003cbr\u003e4. \u003cstrong\u003eDo not insert the battery yet and leave the housing open\u003c\/strong\u003e. Follow the manual of the control panel or receiver. \u003cbr\u003e\u003cbr\u003eThe basic method for learning is as follows:\u003cbr\u003e1. Activate the learn mode by pressing \"1\" in the service mode.\u003cbr\u003e2. Insert the battery into the detector to register the detector.\u003cbr\u003e3. Exit the enrollment mode by pressing \"#\".\u003cbr\u003e\u003cem\u003eTo register the detector if the battery has already been installed; Remove the battery and then press the tamper switch several times to remove residual voltage.\u003c\/em\u003e\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e2 DIP switches\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eMW ON \/ MW OFF\u003c\/strong\u003e This allows the \u003cstrong\u003einternal\u003c\/strong\u003e magnetic contact \u003cstrong\u003edisabled\u003c\/strong\u003e if only an external sensor is connected.\u003cbr\u003e\u003cstrong\u003eINS v DEL\u003c\/strong\u003e With INS an alarm will be generated immediately when the detector is activated, DEL will start the input delay when the control panel is armed. The DIP switch (INS\/DEL) only has effect if the detector in the Oasis control panel is set to \u003cstrong\u003eneutral response\u003c\/strong\u003e.\u003cbr\u003e\u003cem\u003eIt has no effect if the detector is used with a UC-8X or an AC-8X receiver. Opening the housing will result in a tamper message.\u003c\/em\u003e\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e3 Open\/close status detection\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eThe factory setting of the detector allows it to report both the opening and closing of a door or window to the central unit. If you want only the opening of a door or window to be reported, press and hold the tamper switch when the battery is inserted.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e4 Connecting external sensor\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eExternal sensors can be connected to the detector. It is possible to protect multiple doors or windows or to connect other wired detectors. There are 2 entrances, \u003cstrong\u003eIN\u003c\/strong\u003e and \u003cstrong\u003eTMP\u003c\/strong\u003e which will respond when disconnected from the community \u003cstrong\u003eGND\u003c\/strong\u003e connection\u003cbr\u003eIN: If the IN connection is disconnected from the GND connection, the detector will be the same \u003cstrong\u003esignal\u003c\/strong\u003e send to the center \u003cstrong\u003eas if its own magnet were removed\u003c\/strong\u003e of the detector. The internal sensor can be disabled using the DIP switch if desired \u003cstrong\u003eis.\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTMP:\u003c\/strong\u003e The TMP connection will send a tamper signal when it is disconnected from the GND connection.\u003cbr\u003e\u003cstrong\u003ePlease note\u003c\/strong\u003e: If one of the two inputs is not used, it must be short-circuited to the GND connection\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2029.jpg\" width=\"480\" height=\"360\"\u003e \u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e5 Testing the detector\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eUp to 15 minutes after closing the housing, the LED indicator will light up when the door or window is opened or closed. The signal strength can be measured by the control panel in Service mode.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e6 Replace battery\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eThe detector monitors the battery voltage. If this becomes too low, the detector will send a signal to the control panel to warn the user or technician. The detector will continue to operate and the LED will flash each time the detector is activated. Battery replacement should not be delayed longer than 2 weeks. Replacement must be done by a certified installer when the control panel is in Service mode.\u003cbr\u003eDo not just throw away empty batteries, follow the local rules for disposing of batteries.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e7 Removing the detector from the system\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eIf the detector needs to be removed, first remove it from the control panel and then remove the detector.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e8 Technical parameters\u003c\/h3\u003e\r\n\u003ctable border=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan\u003eVoltage:\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e  Lithium battery type CR14250SL (1\/2 AA 3.0V)\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan\u003eNormal battery life:\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e  About 3 years with max. 20 activations per day\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan\u003eCommunication band:\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e  868 MHz, Oasis protocol\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan\u003eRange:\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e  Approximately. 300m (open field)\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan\u003eNormal detection range of the internal sensor:\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e  45\/25mm\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cspan\u003eDimensions: \u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e  110 x 31 x 26 mm\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eInputs for external sensors IN and TMP = normally closed loops\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e\u003cbr\u003e \u003c\/p\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/8860\/2689\/collections\/jablotron-ja-81m.jpg?v=1761583488","url":"https:\/\/www.alarma-total.es\/en\/collections\/ja-81m.oembed","provider":"Alarma-Total.es","version":"1.0","type":"link"}