{"title":"JA-85P","description":"\u003ch2 style=\"text-align: justify;\"\u003eService explanation for JA-85P\u003c\/h2\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e1 Installation\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2017.jpg\" width=\"480\" height=\"360\"\u003e\u003cbr\u003e\u003cbr\u003eInstallation must be carried out by certified installers authorized by the distributor. The detector can be mounted on the wall or on the ceiling. In a car it can be placed between the front and rear seats. Regarding to the detection options, avoid rapidly changing temperature devices, such as electric heaters, and moving objects that come close to body temperature. Blinding of the device for detection is present. Avoid rapid air circulation and do not place objects that could obstruct the view. Keep the detector away from metal objects, which may affect radio communications.\u003cbr\u003eWarning: The most frequent false alarms are due to poor projection. Do not switch on the system when people or animals are present in the secured area\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eRemove the installation base plate\u003c\/strong\u003e (by turning it clockwise).\u003cbr\u003e\u003cstrong\u003e1. Place the base plate\u003c\/strong\u003e at the projected location and place the detector back into the base plate.\u003cbr\u003e\u003cstrong\u003e2. Open the detector\u003c\/strong\u003e by pressing the ta on the housing\u003cbr\u003e\u003cstrong\u003e3. Remove the internal PIR module\u003c\/strong\u003e which is attached to a holder.\u003cbr\u003e\u003cstrong\u003e4. Set the PIR detector of your choice.\u003c\/strong\u003e (*see the DIP switches, below)\u003cbr\u003e\u003cstrong\u003e5. Replace the PIR in the housing\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e6. Do not insert batteries yet and keep the case\u003c\/strong\u003e The detector can now be programmed. While the programming mode is open and on the correct zone numbering, insert the batteries. The detector will be programmed automatically.\u003cbr\u003e\u003cstrong\u003e7. After the detector has been programmed, close the guard\u003c\/strong\u003e until the indicator is off and then test functionality. To program a detector after a battery has been installed, first remove the battery. Wait 30 seconds and reinsert the batteries.\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003e8. DIP switches\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003ctable border=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003e#\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eOFF\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eON\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\n\u003cstrong\u003eNormal insensitivity\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003efor false alarms\u003c\/span\u003e\n\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOver-sensitivity\u003c\/strong\u003e for false alarms with a slower response\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003e2*\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eEntry delay natural reaction\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNo delay\u003c\/strong\u003e natural reaction\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003e3**\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003eRadio \u003cstrong\u003esupervision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003eRadio \u003cstrong\u003esupervision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003e4***\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5 minutes of sleep\u003c\/strong\u003e fashions\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1 minute of sleep\u003c\/strong\u003e fashions\u003c\/span\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e* \u003cstrong\u003eThese DIP switches\u003c\/strong\u003e have an effect when the system is used with a car alarm or with the OASIS control panel. Whose zone is programmed. It has no effect if this detector is used in combination with a UC-8x or AC-8x receiver.\u003cbr\u003e** \u003cstrong\u003eThe Supervision\u003c\/strong\u003e radio communication must be turned off if the detector is installed in a car. This is to prevent a message of lost communication when the car drives away.\u003cbr\u003e*** \u003cstrong\u003eSaving battery energy\u003c\/strong\u003e. The battery setting automatically switches to energy saving mode 15 minutes after the case is closed. During energy saving mode, the detector responds immediately after it detects movement. It then returns to sleep mode, which is selected for 1 min or 5 minutes. However, any motion detection will be ignored during the selected sleep mode. After this period, the PIR detector will transmit another detection when it has been detected. This keeps repeating itself.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e2 Testing the detector\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e15 minutes after the housing is closed, the LED indicator will illuminate and report any movement detected to the OASIS control panel. This must be in the service position. The strength and quality of communication can also be read.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e3 Replacing the battery\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eThe battery quality will be checked regularly. If the battery voltage is too low, the user or installer will be notified. If the battery voltage is low, the detector's LED will light up whenever movement is detected. The battery should be replaced by a qualified technician within two weeks. \u003cbr\u003e\u003cem\u003eAfter replacing the battery, the detector needs two minutes to stabilize. The LED indicator remains on permanently for two minutes. After the battery has been replaced, test the detector for functionality. Batteries must be returned to the local collection point.\u003c\/em\u003e\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e4 Detection range\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eThe detector responds to movements within a range of 5 meters. * see table below.\u003cbr\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2018.jpg\" width=\"480\" height=\"360\"\u003e \u003c\/p\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/8860\/2689\/collections\/ja-85p-wireless-pir-detector-pacific-gsm-oasis-ala.jpg?v=1761583481","url":"https:\/\/www.alarma-total.es\/en\/collections\/ja-85p.oembed","provider":"Alarma-Total.es","version":"1.0","type":"link"}