{"title":"JA-89P","description":"\u003ch2 style=\"text-align: justify;\"\u003eService explanation for JA-89P\u003c\/h2\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e1 Installation\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eChoose the right place to mount the detector taking into account the following:\u003cbr\u003e1. Install the detector perpendicular to the ground to have the upper detection area detected parallel to it.\u003cbr\u003e2. Installation height is 0.8 – 1.2 m\u003cbr\u003e3. Mount the detector in such a way that most of the movement area falls within the detection pattern.\u003cbr\u003e4. Too much light such as strong sunlight directly on the sensor may cause an unstable condition. It is highly recommended to avoid this.\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2035.jpg\" width=\"480\" height=\"360\"\u003e\u003cbr\u003e\u003cbr\u003eTo open the detector:\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e1. Unscrew the lock and remove the top of the case.\u003cbr\u003e2. Unscrew the screws from the back plate. Remove the base plate.\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eNOTE: never touch the surface of the PIR sensor.\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eAttach the detector to the desired location. The detector can be placed directly on the wall or used on the post (Ø 43 – 48 mm) using the supplied mounting bracket.\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2036.jpg\" width=\"480\" height=\"360\"\u003e \u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e2 Teaching the detector into the receiver\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eThe transmitting module is placed under the optical part of the detector. First study the installation manual of the receiving unit (control panel) to learn how to enter the learn mode. When the receiver is in learning mode, insert the batteries into the detector (polarity is indicated in the detector). The detector will give a learning signal after the batteries have been installed.\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2037.jpg\" width=\"480\" height=\"360\"\u003e \u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cem\u003eJA-81M transmission module\u003c\/em\u003e\u003cbr\u003e· Use DIP switch no. 1 to change the system response:\u003cbr\u003e- direct (ON position)\u003cbr\u003e- delayed (position 1).\u003cbr\u003e· Leave DIP switch no. 2 in the ON position.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e3 Adjustment\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eThe upper detection area remains parallel to the ground. The lower area moves as shown below depending on the position of the switch. The detection length is therefore limited by the length of the lower detection area, since the upper and lower areas must both be activated at the same time to activate the detector.\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2038.jpg\" width=\"480\" height=\"360\"\u003e \u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eDetection length setting table:\u003c\/p\u003e\r\n\u003ctable border=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003ePosition \u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eMax. detection length \u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cem\u003eStandard\u003c\/em\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cem\u003eSee \u003cstrong\u003ePLEASE NOTE\u003c\/strong\u003e under table\u003c\/em\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eA\u003c\/td\u003e\r\n\u003ctd\u003e12 m\u003c\/td\u003e\r\n\u003ctd\u003e10.0 to 15.0 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eb\u003c\/td\u003e\r\n\u003ctd\u003e8 m\u003c\/td\u003e\r\n\u003ctd\u003e6.0 to 10.0 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003ec\u003c\/td\u003e\r\n\u003ctd\u003e5 m\u003c\/td\u003e\r\n\u003ctd\u003e4.0 to 5.5 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eD\u003c\/td\u003e\r\n\u003ctd\u003e2 m\u003c\/td\u003e\r\n\u003ctd\u003e1.5 to 2.5 m\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eNOTE: The maximum detection length may vary as above due to environmental temperature conditions.\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2039.jpg\" width=\"480\" height=\"360\"\u003e\u003cbr\u003e\u003cbr\u003eActive area angle is 90°. By holding the pyroelectric unit it can be rotated in the desired direction (in 15° increments).\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2040.jpg\" width=\"480\" height=\"360\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDemarcate area\u003c\/strong\u003e – the detection area that is exposed to the reflection of sunlight, car light, etc. can be shielded using the supplied shielding plates.\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eSensitivity of the PIR sensor can be adjusted at the \"SENS\" switch in 3 steps:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eL\u003c\/strong\u003e - low\u003cbr\u003e\u003cstrong\u003eM\u003c\/strong\u003e - medium\u003cbr\u003e\u003cstrong\u003eH\u003c\/strong\u003e - high\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOther settings can be changed with a DIP switch:\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2042.jpg\" width=\"480\" height=\"360\"\u003e\u003cbr\u003e\u003cbr\u003eThe LED indicator is used for testing the PIR detector. During normal use it is recommended to turn it off to save batteries.\u003cbr\u003eDepending on the setting of the 120s\/5s battery saving timer DIP switch, the motion sensor will be blocked for a period of 5 or 120 seconds after motion is detected or to save batteries.\u003cbr\u003eDepending on the position of the pulse count DIP switch, the detector (above \u0026 below detection area) must be activated 2 or 4 times to send an alarm signal.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e4 Operation test\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eTurn on the LED indicator, set the \"battery save timer\" to 5 seconds and close the detector. Every 5 seconds, any movement in the detection area will be displayed by the LED indicator and the alarm information will be sent to the control panel.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e5 Operation\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eTo extend the battery life, it is highly recommended to set the \"battery saving time\" to 120 seconds and turn off the LED indicator in normal condition. The motion sensor will be shielded for 5 or 120 seconds after detecting a motion. This means that if there is constant movement in the area, the detector will only send this movement information once every 5 or 120 seconds.\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e6 Test and replace batteries\u003c\/h3\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eThe detector checks its battery status automatically. If it is necessary to replace the batteries, the detector will inform the system. When battery replacement is displayed, they should be replaced as soon as possible (within one week).\u003cbr\u003eBefore replacing the batteries, the receiver (control panel) must be set to the mode that allows the detector to be opened (User or Programming mode).\u003cbr\u003eUse only high quality AAA alkaline batteries for replacement\u003cbr\u003e\u003cem\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e Destroy batteries safely depending on the type and local regulations. Although this product does not contain harmful materials, we recommend that you return the product immediately to the factory or seller after use.\u003c\/em\u003e\u003c\/p\u003e\r\n\u003ch3 style=\"text-align: justify;\"\u003e7 Troubleshooting\u003c\/h3\u003e\r\n\u003cdiv\u003e\u003c\/div\u003e\r\n\u003ctable border=\"0\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003cstrong\u003eProblem \u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eProbable cause\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cstrong\u003eSolution\u003c\/strong\u003e\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDetector gives false alarm\u003c\/td\u003e\r\n\u003ctd\u003eLower detection area is unnecessarily long.\u003c\/td\u003e\r\n\u003ctd\u003eSet the detection area properly.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003eDetection area receives reflection from the reflector, sunlight, car light, etc. \u003c\/td\u003e\r\n\u003ctd\u003eRemove the reflector, shield the area exposed to the reflection of light or change the position of the detector.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003eThere is a heat source in the area that causes rapid temp. change can cause (oven, stove, etc.)\u003c\/td\u003e\r\n\u003ctd\u003eRemove the source of heat or change the position of the detector\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003eThere is a moving object in the area (clothes on the clothesline, plants, etc.)\u003c\/td\u003e\r\n\u003ctd\u003eRemove the moving object or change the position of the detector.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eOccasionally no detection\u003c\/td\u003e\r\n\u003ctd\u003eDetection area is not set properly\u003c\/td\u003e\r\n\u003ctd\u003eSet the detection area correctly.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003e\u003cspan\u003eSensitivity is too low\u003c\/span\u003e\u003c\/td\u003e\r\n\u003ctd\u003eChange the sensitivity to medium (M) or high (H).\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003eDetector not working\u003c\/td\u003e\r\n\u003ctd\u003eLow battery level\u003c\/td\u003e\r\n\u003ctd\u003eReplace the battery\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003eLED does not light up\u003c\/td\u003e\r\n\u003ctd\u003eSet the LED switch to ON\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd\u003e\u003c\/td\u003e\r\n\u003ctd\u003eLED lights up but no response to the control paneer\u003c\/td\u003e\r\n\u003ctd\u003eThe control panel is out of range, check the battery, try moving the detector or the control panel.\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003e8 Specifications\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003ePower supply 3.6 V - 1 x AA battery Lithium\u003cbr\u003eBattery life approximately 2 years\u003cbr\u003eFrequency 868 MHz\u003cbr\u003eRF strength \u003c 10 mV\u003cbr\u003eRange max. 300 m (open area)\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eSpecification of the Optex VX 402R detector\u003cbr\u003eDetection method Passive infrared\u003cbr\u003eRange 12 m \/ 90° ; 14 segments\u003cbr\u003eMounting height 0.8 – 1.2 m\u003cbr\u003eDetection speed 0.3 – 1.5 ms-1\u003cbr\u003eBattery saving timer 5 or 120 seconds\u003cbr\u003eLED indicator only in test mode\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eEnvironmental class IV (EN 50131-1)\u003cbr\u003eOperating temperature -20°C to +50°C\u003cbr\u003eWater resistant IP54\u003cbr\u003eHumidity 95%\u003cbr\u003eDimensions 198 x 80 x 108 mm\u003c\/p\u003e\r\n\u003cp style=\"text-align: justify;\"\u003eSafety level 2 (EN 50131-1)\u003cbr\u003eCan be used according to ERC\/REC 70-03\u003c\/p\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0937\/8860\/2689\/collections\/jablotron-ja-89p.jpg?v=1761583488","url":"https:\/\/www.alarma-total.es\/en\/collections\/ja-89p.oembed","provider":"Alarma-Total.es","version":"1.0","type":"link"}