JA-110I

No products

There are no products in this collection. Continue shopping.

Service explanation for JA-110I

BUS section / output PG activation indicator

This product is part of the JABLOTRON JA-100 alarm system. It provides an optical indication of the status of the system sections (armed / disarmed) or the status of the programmable outputs. The product is intended for installation by a trained technician with a valid Jablotron certificate.

Installation
 

1. Open the indicator cover by loosening the four snap clamps using a suitable flat screwdriver, with which you turn in the direction of the arrows.
2. Loosen the click clamp (1) and remove the plate.
 

Image: 1 – click clamp of the plate; 2 – configuration switch; 3 – red signal light of the indicator; 4 – hole to be broken open; 5 – BUS terminals

3. Use the switch (2) to set the number of the section that requires indication (see Tab. 1) or PG output (see Tab. 2).
4. Pull the cable through the opening (4) and attach the back wall of the indicator to the chosen location.
5. Fold back the indicator plate and connect the bus cable to the terminals (5).
Before connecting the BUS, the system must be disconnected from the power supply.

If the indicator is located outside the area to be monitored, its BUS supply must be isolated with a JA-110T bus isolator.

6. After turning on the system, test its operation.
7. Replace the indicator cover.
 

Tab. 1 Section indication setting

Tab. 2 Setting for indication of a Pg output

Notes:
- Indicator does not occupy a position in the control panel (it is not assigned to the system).
- Multiple connected modules with the same setting will give the same indication.
- Number of indicators is only limited by power consumption from the power station.

 

Image: JA-110I indicator dimensions.

Technical parameters
Power supply from the BUS of the central unit 12 V (9 ...15 V)
Power consumption on standby (LED on / off) 6 mA / 3 mA
Power consumption for choice of cable 6 mA
Dimensions 62 x 36 x 27 mm
Classification grade 2
in accordance with EN 50131-1, EN 50131-3
Environment according to EN 50131-1 II. inside, general
Working temperature range -10 to + 40 °C
Furthermore complies with EN 50130-4, CSN EN 55022

Product JA-110I is designed and manufactured in accordance with the provisions applicable to it: Government Decree No. 17/2003 Coll. and 616/2006 Sb., provided that it is used according to its intended purpose. Original Declaration of Conformity can be found at www.jablotron.cz in the advice section.

Note: Although this product does not contain harmful materials, do not dispose of it in the household waste, but hand it in at the collection point intended for electronic waste. 