JA-111I

No products

There are no products in this collection. Continue shopping.

Service explanation for JA-111I

BUS LED indicator RGB

This product is part of the JABLOTRON JA-100 alarm system. It serves for optical indication of the status. The color of the indication is optional by means of the connection, for example, the indicator can indicate the controlled output in two colors (red / green). The product is intended for installation by a trained technician with a valid Jablotron certificate.

Installation
 

1. Open the indicator cover by loosening the four snap clamps using a suitable flat screwdriver, with which you turn in the direction of the arrows.
2. Loosen the click clamp (1) and remove the plate.


Image: 1 – click clamp of the plate; 2 – indicator signal light; 3 – hole to be broken open for supply cable; 4 – terminals

3. Pull the supply cable through the opening (3) and attach the back wall of the indicator to the chosen location.
4. Click the indicator plate back in.
5. Connect the cable to the terminals (4) according to the chosen color for indication by means of. a signal light (2), see table:

+U supply of 12 V voltage
R red red light, when closed on GND
G green green light, when closed on GND
B blue blue light, when closed to GND
Y yelow yellow light, when closed to GND

6. Test the operation after switching on the system.
7. Place the indicator cover on.

Function
The indicator is designed for indoor indication, also outside the monitored area. If it is installed outside the monitored area, the voltage applied to the +U terminal (if tapped from the system BUS) must be protected against short circuit, e.g. with a JA-110T bus isolator module.
 

Image: Example of the connection for a two-color indication of the PG output status

 

Image: Dimensions of a JA-111I indicator.

Technical parameters
Power supply 12 V (9 ...15 V)
Power consumption on standby (LED on / off) 5 mA / 0 mA
Power consumption for choice of cable 5 mA
Dimensions 62 x 36 x 27 mm
Environment according to EN 50131-1 II. inside, general
Working temperature range -10 to + 40 °C

Note: Although this product does not contain harmful materials, do not dispose of it in the household waste, but hand it in at the collection point intended for electronic waste.