Service explanation for JA-111N
BUS signal output module PG
This product is part of the JABLOTRON JA-100 alarm system. It provides a switching contact of the output relay. It can be used, for example, to operate an electric door lock, blocking, indication, and the like. The relay can be operated by a programmable output of the control panel, furthermore by the status of the section (armed = relay contact on), possibly by an alarm in the section (alarm = relay contact on). The product is intended for installation by a trained technician with a valid Jablotron certificate.
Installation
The module can be installed in a JA-190PL (Jablotron) mounting box.

Image: 1 – BUS terminals; 2 – red signal light of relay switched on, 3 – configuration switch, 4 – output relay, 5 – terminals of the relay.
1. Use the switch (3) to set the number of the output or section to which the relay should respond - see setting tables.
2. Connect the bus cable to the terminals (1).
Before connecting the BUS, the system must be disconnected from the power supply.
If the module is located outside the area to be monitored, its BUS supply must be isolated with a JA-110T bus isolator.
The output contact has no overload protection.
3. Test the operation after switching on the system.
4. Check whether the supply voltage on the bus terminals (red, black) is greater than 9V when relay contacts are closed.
5. Connect the equipment to be switched on to the terminals of the relay (5).
Notes:
- The module does not occupy a position in the control panel (is not assigned in the system).
- With multiple connected modules with the same setting, their relays perform the same function.
- The number of modules is only limited by power consumption from the central unit.
- Setting of individual programmable outputs is done by the F-Link program - PG outputs card. Detailed description of settings can be found in the installation manual of the control panel.
- If the output responds to the arming of the section, the relay is switched on when the selected section is fully or partially armed.
- If the output responds to alarm, the relay is switched on for any type of alarm.


Table 1: output responds to status of the PG output.
Table 2: Output responds to section reinforcement
Table 3: output responds to alarm in the section
Technical parameters
Power supply from the BUS of the central unit 12V (9...15V)
Power consumption on standby (relay off/on) 5 mA / 25 mA
Power consumption for choice of cable 25 mA
Possible loading of relay contacts:
Max. excitation voltage 50 V AC / 60V DC
Max. excitation current max.2A
Min. excitation current 10 mA
Dimensions 70 x 38 x 15 mm
Classification grade 2
in accordance with EN 50131-1, EN 50131-3
Environment according to EN 50131-1 II. inside, general
Working temperature range -10 to +40 °C
Furthermore complies with EN 50130-4, EN 55022