Service explanation for JA-150P
Wireless PIR detector
This product is part of the JABLOTRON JA-100 alarm system. It provides spatial detection of movement of people within buildings. The detection characteristic can be changed by using an alternative lens. False alarm immunity is optional, on two levels. The detector has a pulse response (only reports its own activation), communicates wirelessly and is powered by two alkaline batteries. The product is intended for installation by a trained technician with a valid Jablotron certificate.
Installation
The detector can be installed on a wall or in a corner of the room. There should be no objects that change temperature quickly (electric heaters, gas appliances, etc.), no moving objects (e.g. billowing curtains above a radiator) or pets within his field of vision. It is not recommended to install the detector opposite windows or reflectors, not even where there is air flow (ventilation, air conditioning, draft holes, non-closing doors, etc.). There should be no objects in front of the detector that obstruct the view.
Image: 1 – holes for mounting on a flat wall; 2, 4 – holes for mounting in a corner; 3 – click clamp of the electronics plate; 5 – hood snap clamp;
1. Open the detector cover (by pressing the click clamp 5). Do not touch the PIR sensor (11) inside - so as not to damage it.
2. Remove the electronics - they are attached to the click clamp (3).
3. Make holes for screws in the plastic back wall and place it on the wall. The recommended height for installing the detector is 2.5 m above the floor.
4. Set the Immunity interconnection as required, see the detector setting.
5. Replace the electronics and follow the installation manual of the control panel. Basic steps:
a. The control panel must have the JA-110R radio module.
b. In the F-Link program, select the desired position on the Peripherals card and start the learning mode with the Read button.
c. Insert the batteries (note correct polarity). When the second battery is installed in the detector, the learning signal will be sent to the control panel and the detector will learn the selected position. The detector is stabilizing (this can take up to three minutes), which can be recognized by the signal light on.
6. Close the detector cover and check operation.
Image: 6 – red activation signal light; 7 – batteries; 8 – adjustable Immunity interconnection; 9 – serial number; 10 – tamper switch; 11 – PIR sensor;
Notes:
If you want to teach the detector in the receiver after the battery has already been connected, first disconnect the battery, then press and release the screen contact (10) (to consume the residual energy) and then let the detector learn.
The detector can also learn into the system by entering the serial number (9), via the F-Link program, or via the keypad (or via barcode reader). All numbers below the barcode must be entered (1400-00-0000-0001).
Set detector
Immunity level can be set using the jumper on the electronics board in the detector and determines immunity against false alarms. NORM (factory setting) combines basic immunity with a fast response. HIGH is increased and provides better immunity, but the detector responds more slowly.
Working modes of the detector
The detector has 2 modes, which are indicated by one or two flashes when the battery is inserted.
One flash means that the detector is operating in Smartwatch mode, intended for permanent monitoring of movement in the confined space. If permanent motion is detected, three notifications are sent, each time after 20 seconds, then the next notification is only sent after 2 minutes. If no permanent movement is detected for 10 minutes, the three-notification mode returns every 20 seconds.
Two flashes mean One-minute interval mode. After motion is detected, the detector goes to sleep for 1 minute, after which time it is active again for the entire time until the next detection.
The working mode is determined in such a way that when inserting the batteries, you press and hold the screen contact of the detector (10), insert the battery and release it after 3 - 5 seconds. The detector flashes once or twice depending on the currently set mode. The Smartwatch mode is set at the factory.
Test detector
For 15 minutes after closing the detector cover, the signal light indicates any movement and reports it to the control panel. After this period, the detector switches to the mode selected when the battery was inserted.
The detector can also be operated using the F-link program can be checked in the Diagnostics bookmark.
Replace batteries in the detector
The system automatically reports that the batteries are running low. Before replacing the batteries in the detector, the system must switch to Service Mode (otherwise a tamper alarm will be raised).
Detection characteristic
The detector is equipped with the 110°/12m lens from the factory. The space is covered by 3 fans (curtain fields) – see the following image.
The characteristic can be changed by using an alternative lens:
JS-7904 is intended for long corridors, has a range of up to 20m
With this lens the higher level of analysis cannot be used!
JS-7906 only has the top curtain field of 120°/12m and does not cover the floor (can eliminate movement of small animals across the floor)
JS-7901 vertical curtain field – does not cover the surface, but creates a detection wall (a barrier can be defined, any crossing is reported)
Note: After replacing the lens, check whether the detector covers the space properly (an incorrectly installed lens can cause a detection error).
Technical parameters
Power supply 2 pcs. alkaline battery AA (LR6) 1.5 V 2400mAh
Typical battery life approx. 2 years (longest in the
smartwatch mode)
Communication band 868.1 MHz, protocol JABLOTRON
Communication range approx. 300 m (free terrain)
Recommended installation height 2.5 m above the floor
Detection angle / detection coverage 110° / 12 m (with basic lens)
Dimensions 95 x 60 x 55 mm
Classification grade 2
according to EN 50131-1, EN 50131-2-2,
Environment according to EN 50131-1 II. inside, general
Working temperature range -10 to +40 °C
Furthermore complies with EN 50130-4, EN 55022
Product JA-150P is designed and manufactured in accordance with the provisions applicable to it: Government Decree No. 616/2006 Coll., provided it is used according to its intended purpose. Original Declaration of Conformity can be found at www.jablotron.cz in the advice section.
Note: Although this product does not contain harmful materials, do not dispose of it in the household waste, but hand it in at the collection point intended for electronic waste.